Mercedes-Benz · SD Connect C4 / C6 · SCN Coding · Online Programming

Mercedes-Benz SD Connect Remote Diagnostics:
XENTRY, SCN Coding and DTS Monaco via eLinehub

SD Connect C4 or C6 appears as a local Ethernet VCI on the Technician’s PC — XENTRY, DTS Monaco and Vediamo run on your own machine with your own credentials. No hardware relay box. No remote desktop.

  • ✓SD Connect appears on the expected 172.29.x.x subnet — XENTRY discovers it as a locally connected device
  • ✓Check compatibility for the exact vehicle, software and interface before starting. The examples on this page do not establish coverage for every combination.
  • ✓The workshop only needs eLinehub Mechanic (free) — no XENTRY install, no credentials, no subscription at the workshop

The workshop provides the vehicle and SD Connect. You bring XENTRY, DTS Monaco or Vediamo and your Mercedes Online credentials. eLinehub provides the bridge. · By eLinehub ·

Who uses this page
Independent Diagnostic Technician
You hold XENTRY, DTS Monaco or Vediamo with a Mercedes Online account and want to perform coding and programming for workshops without traveling to each job.
Tool, Parts & Training Provider
You supply diagnostic tools, OEM parts or training services to workshops and want to include remote SCN coding and programming as part of your service offering.
Repair Shop Chain or Fleet Operator
You run multiple workshop locations or a commercial vehicle fleet and need remote ECU programming coverage without dispatching a specialist to each site.
1 — SCN Coding & Online Coding Requirements

Mercedes-Benz SCN Coding and the SD Connect Setup

This page describes an SD Connect network-bridging setup for XENTRY on a Technician PC. The VCI and network configuration requirements depend on the Mercedes-Benz diagnostic solution being used. Mercedes-Benz also offers XENTRY Pass Thru EU for supported vehicles and devices, with its own limitations. A network connection does not establish the account eligibility or authorization needed for an individual coding or programming job.

For each replacement module, check the vehicle-specific procedure and required software, device and account access.

  • ME Engine Control Unit

    W205 C300/C43 · W213 E300/E350/E63 · W222 S550/S63 · W167 GLE350/GLE63

    Flash and SCN coding are two separate steps. A successful flash without SCN leaves the ECU functional but uncoded — fault codes remain active, and follow-up SCN sessions on a partial-flash ECU carry additional risk.

  • 722.9 VGS / TCM — Conductor Plate

    W212/W213 E-Class · W204/W205 C-Class · W221/W222 S-Class · W166/W167 GLE/GLS/ML/GL

    The conductor plate is a technically restricted part (TRP). New and replacement units require VeDoc re-documentation, a software flash and SCN coding. One of the highest-frequency SCN jobs on Mercedes-Benz vehicles.

  • SAM — Signal Acquisition Module

    W204, W205, W212, W213 — particularly rear SAM on E-Class

    Replacement SAMs arrive uncoded. Without SCN coding the vehicle will not lock remotely, will not respond to the key correctly, and shows a raft of CAN communication faults.

  • ABS / ESP Control Unit

    Check the vehicle and replacement-module requirements

    Use the applicable Mercedes-Benz procedure to determine whether the replacement requires SCN coding and which diagnostic solution and account access are needed. Device connectivity alone does not establish authorization.

  • SRS Airbag Control Unit

    Check the vehicle-specific replacement procedure

    Follow the applicable Mercedes-Benz procedure for replacement, coding and verification of the SRS control unit. Do not infer the required online steps or repair completion from the connection method alone.

  • COMAND / MBUX Head Unit

    NTG5 through NTG7

    Units sourced from breakers arrive uncoded. XENTRY must write the SCN number matched to the car’s VIN and option configuration before audio, navigation or telephony functions become active.

  • Door Control Units (DCU)

    Several model years per Mercedes service bulletins

    A replaced DCU reads as invisible in XENTRY quick test and produces a permanent chassis communication fault until coded.

  • EIS / EZS — Ignition & Steering Lock

    Check the vehicle and keyless-system variant

    Check the applicable Mercedes-Benz replacement and matching procedure for the keyless-system module, including any online authentication requirements. The SD Connect bridge does not provide that authorization.

2021+ Vehicles — Secure Gateway

W206 C-Class, W223 S-Class, X167 GLE/GLS facelift, W214 E-Class, EQS (V297) and EQE (Z295): in addition to standard SCN requirements, XENTRY requires a Xentry diagnostic certificate (ZenZefi format) for offline guided diagnostics and adaptations on modules behind the vehicle’s secure gateway. The certificate is held by the Technician independently — eLinehub bridges the SD Connect and does not affect how XENTRY authenticates or uses the certificate.

2 — Architecture Problem

Remote Desktop Control vs SD Connect Network Bridging

In a workshop-PC architecture, XENTRY runs on the workshop computer and uses that computer’s configured connection to SD Connect. If XENTRY runs on a separate Technician PC, that computer needs its own supported path to the workshop VCI. Screen control alone does not create that path; software, device and configuration requirements still apply.

  • SD Connect Network Configuration

    SD Connect network settings depend on the device and software configuration. Screen control of the workshop computer does not by itself establish the required VCI connection for XENTRY running on a separate Technician PC.

  • SCN Coding Session Integrity

    SCN coding requires an uninterrupted three-way exchange: XENTRY ↔ SD Connect ↔ Mercedes-Benz backend. Any packet reordering or brief disconnect invalidates the SCN session and may leave the ECU with a blank or partial calibration number.

  • DoIP Topology Scans on MRA2 / EVA2 / MMA

    Newer Mercedes-Benz architectures generate sustained high-packet-per-second DoIP bursts during ECU discovery. Generic VPNs and consumer routers silently reorder or buffer these packets, breaking XENTRY’s protocol timing.

  • DTS Monaco and Vediamo TCP/IP Dependency

    In the SD Connect setup described here, the computer running DTS Monaco or Vediamo needs a configured connection to the VCI. Controlling the workshop computer does not itself provide a VCI connection for software running on a separate Technician PC.

  • Credential and Account Exposure Risk

    With remote desktop, XENTRY runs on the workshop PC. Assess that computer’s software licensing, account access and security arrangements before using it. Remote control alone neither establishes permission to use an OEM account nor requires sharing its credentials with the workshop.

eLinehub bridges the SD Connect’s physical network adapter at Layer 2 across the internet. XENTRY, DTS Monaco and Vediamo on the Technician PC see an Ethernet adapter on the expected 172.29.x.x subnet — no screen share, no protocol translation, and all credentials stay exclusively on the Technician’s machine.

3 — Network Bridging

How eLinehub Works with SD Connect

eLinehub bridges the workshop’s shared SD Connect network connection to the Technician PC. Choose the target adapter for the specific VCI and connection. Keep Link for configurations that already work with it. For SD Connect C4 over RJ45 when XENTRY requires a fixed IP, use physical network bridging. In a local loopback, leave the bridge-side interface on automatic IP and apply the required static address to the separate diagnostic interface.

Tap an image to enlarge it.

①
Layer 2 Bridging — MAC and Broadcast Preservation

The Mechanic shares the network interface connected to SD Connect. The selected interface on the Technician PC receives the bridged Ethernet traffic, including discovery broadcasts.

②
Static IP Aligned with XENTRY Behavior

For SD Connect C4 over RJ45 when XENTRY requires a fixed IP, use physical network bridging. In a local loopback, leave the bridge-side interface on automatic IP and apply the required static address to the separate diagnostic interface. Check the OEM settings for the specific VCI before assigning an address.

③
Low-Jitter, Long-Session Transport

The tunnel avoids aggressive compression, packet reordering and buffering that disturb OEM protocol timing — critical for SCN coding and DoIP programming sessions that run for extended periods with no tolerance for mid-session interruption.

What eLinehub does not do: eLinehub does not provide Mercedes Online accounts, XENTRY licenses, FDOK credentials or SCN access. It only bridges the physical SD Connect network presence from the workshop to the Technician’s PC.
Connection mode: SD Connect uses network adapter bridging, which operates in Relay mode only. Direct/P2P mode applies to USB-mapped devices only.
4 — Device Configuration

SD Connect C4 vs C6 — Remote Setup and Configuration

SD Connect C4

C4 uses a straightforward Ethernet connection with no persistent local management service. Once connected to the workshop PC via LAN cable and recognized as an active network link, it can be shared immediately.

Mechanic setup steps
  1. Connect SD Connect C4 to the vehicle OBD port.
  2. Connect SD Connect C4 to the workshop PC via wired Ethernet (LAN cable) — not WiFi.
  3. Verify Windows shows an active network link on the NIC connected to C4.
  4. Open eLinehub Mechanic and share the network adapter.

SD Connect C6 (and compatible VXDIAG devices)

C6 runs background VCI management processes and services that bind the device to the local PC. If any remain active when eLinehub tries to bridge the adapter, the remote Technician’s XENTRY cannot enumerate the SD Connect. Stop these before sharing.

Processes (Task Manager → Details tab)
VciManager.exeVCIConfig.exeVXManager.exe
Services (services.msc)
Daimler VCI ManagerBosch VCI ManagerDevice ManagementVXDIAG SDKDaimlerVCIIndentService
Note: The processes and services listed above are not all present on every machine — which ones exist depends on the C6 or VXDIAG driver version installed. Stop whichever apply and confirm none remain active. Some C6 firmware versions automatically restart their management service when the device reconnects to power or USB — verify they remain stopped before the Technician launches XENTRY.
Once released, open eLinehub Mechanic and share the C6 network adapter. This release step is required at the start of each remote session.
5 — Step-by-Step Walkthroughs

Real Job Workflows — SCN Coding and ECU Programming via SD Connect

Four complete scenarios covering the most common Mercedes-Benz remote diagnostic and programming jobs.

  • A

    SAM / ME ECU Replacement with SCN Coding

    W205, W212, W213, W222, W167, W223 — nearly any control unit replacement requiring Mercedes Online authentication.

    Mechanic Side

    1. Mechanic connects SD Connect C4 to the vehicle OBD port and to the workshop PC via wired Ethernet (LAN cable).
    2. Opens eLinehub Mechanic, creates the order and shares the Passcode with the Technician.

    Technician Side

    1. Accept the Passcode and select Mechanic Network Adapter. For this fixed-IP SD Connect C4 RJ45 setup, choose a physical network adapter.
    2. Wait until the physical bridge shows connected status before launching XENTRY.
    3. For SD Connect C4 over RJ45 when XENTRY requires a fixed IP, use physical network bridging. In a local loopback, leave the bridge-side interface on automatic IP and apply the required static address to the separate diagnostic interface. Confirm the IP settings and check for conflicts before connecting.
    4. Launch XENTRY Diagnosis and confirm it discovers the SD Connect on the configured diagnostic interface.
    5. Quick test identifies the SAM as present but uncoded. Navigate to SAM → control unit variant coding. Authenticate with Mercedes Online credentials directly through XENTRY. SCN request returns the calibration number and writes it to the SAM.
    6. Before returning the vehicle, record the software result and have qualified staff complete the required on-site checks. A clear fault scan or warning light alone does not establish that the vehicle is ready.
  • B

    722.9 VGS / TCM Conductor Plate Flash and SCN Coding

    W212/W213 E-Class · W204/W205 C-Class · W221/W222 S-Class · W166/W167 GLE/GLS · W164/W166 ML/GL.

    Mechanic Side

    1. Gearbox reinstalled, conductor plate connector seated. Mechanic connects SD Connect C4, creates the order and shares the Passcode.
    2. Before work, use the VIN and the manufacturer’s service information to confirm the module, interface, vehicle power and ignition requirements.
    3. After the Technician resets the transmission adaptations, carry out the brief adaptation drive cycle under their guidance to re-establish shift pressure learning.

    Technician Side

    1. Accept the Passcode. For the SD Connect C4 fixed-IP RJ45 setup, follow the physical bridging and diagnostic-interface steps in Scenario A.
    2. XENTRY quick test shows the VGS as unprogrammed or with a mismatched SCN number against the vehicle ECM.
    3. After the Mechanic confirms that the programming power supply is ready: Navigate to VGS → control unit adaptations → SCN coding update. XENTRY contacts the Daimler SCN server, pulls the correct software flash file for the VIN and writes it to the conductor plate.
    4. SCN coding assigns the calibration number. VGS is now matched to the VIN.
    5. Before returning the vehicle, record the software result and have qualified staff complete the required on-site checks. A clear fault scan or warning light alone does not establish that the vehicle is ready.
  • C

    DoIP ECU Programming — W907, W206 and EVA2 Platforms

    Required for any module work on 2019+ vehicles. Particularly relevant for Sprinter W907 fleet operators.

    Mechanic Side

    1. Mechanic stops all C6 VCI management processes and services (see Section 4). Connects C6 to the W907 OBD port and workshop PC via LAN cable. Creates the order.
    2. Connect a programming power supply before the Technician starts the ECM flash and maintain it throughout programming.

    Technician Side

    1. Accept the Passcode and confirm the SD Connect model and connection. Keep Link for an existing supported Link setup. Follow Scenario A only if the RJ45 connection requires a fixed IP.
    2. XENTRY runs a DoIP topology scan — a high-packet-per-second broadcast enumerating every ECU on the vehicle’s Ethernet backbone. The eLinehub tunnel passes this traffic without reordering; the scan completes at normal speed.
    3. XENTRY identifies the replacement ECM as unconfigured and opens the guided programming sequence.
    4. If the W907’s DoIP network gateway causes the Technician’s internet to drop while the diagnostic session stays active, use the Switch button in eLinehub to toggle between diagnostic priority mode and normal internet mode. Toggle only between sessions — never during SCN coding or a flash.
    5. After the Mechanic confirms that the programming power supply is ready: XENTRY downloads the software file and begins the ECM flash. A full ECM flash on W907 over DoIP typically runs 8–14 minutes on a stable connection.
    6. Before returning the vehicle, record the software result and have qualified staff complete the required on-site checks. A clear fault scan or warning light alone does not establish that the vehicle is ready.
  • D

    Radar and ADAS Initialization After Collision Repair

    W205, W213, W167, W206 and any chassis with Active Brake Assist, Blind Spot Assist or Distronic.

    Mechanic Side

    1. Confirm body repair is complete. Verify all radar sensors and cameras are reinstalled in the original mounting positions before any software work — initialization will not compensate for a physically misaligned sensor.
    2. SD Connect C4 connected to vehicle OBD port and workshop PC via LAN cable. Mechanic creates order and shares Passcode.
    3. Before returning the vehicle, record the software result and have qualified staff complete the required on-site checks. A clear fault scan or warning light alone does not establish that the vehicle is ready.

    Technician Side

    1. Accept the Passcode and confirm the SD Connect model and connection. Keep Link where already supported. Use physical bridging as in Scenario A only for a fixed-IP RJ45 connection.
    2. XENTRY quick test — note and record all active fault codes in BSM, ESP, radar and camera modules before beginning any initialization. Some codes are historical artifacts from the repair; others may indicate sensor damage or misalignment that must be resolved physically before proceeding.
    3. Navigate to SRR module → adaptations → radar sensor initialization. Rear SRR sensors use a dynamic teach-in requiring no physical calibration target — the initialization runs entirely in software.
    4. Use the procedure for this vehicle and module to determine which programming, relearn or calibration steps apply. Allow time for the required checks.

Ready to run your first remote XENTRY session?

Sign in to the Technician Web App to check your account’s current trial eligibility and terms.

6 — Advanced Engineering Tools

DTS Monaco and Vediamo Remotely via SD Connect

The computer running DTS Monaco or Vediamo needs the VCI interface configured for its device and software version. A screen-control session operates the workshop computer. When the tool runs on a separate Technician PC, it needs its own supported connection to the workshop VCI. eLinehub provides device/network mapping for that architecture; relevant driver and network settings still apply.

DTS Monaco — Remote Workflows

  • Custom .mdiag sequence execution
  • Parameter-level ECU modification on AMG, Maybach and high-spec variants
  • Seed-key authentication for protected ECU functions
  • Raw CAN and DoIP trace capture
  • Retrofit and hidden option enablement via engineering-level access

Vediamo — Remote Workflows

  • Direct ECU flash via .smr-d container scripts
  • Variant coding with full parameter visibility
  • SFD-equivalent engineering access on MRA2 platform ECUs
  • Session state logging and parameter comparison across multiple vehicles
Note: DTS Monaco and Vediamo sessions should run on the same PC as XENTRY. Running them from a separate machine while sharing a single SD Connect session is technically possible but not recommended for programming workflows.
7 — Installation Guide

End-to-End Setup — Mechanic and Technician

System requirements: Windows 7 64-bit minimum; Windows 10 or 11 64-bit recommended. Not supported on Mac, Linux, Android or Windows ARM.
  • Mechanic Side — Workshop

    Free to use. No OEM software or subscription required.

    1. Connect SD Connect C4 or C6 to the vehicle OBD port and to the workshop PC via wired Ethernet (LAN cable) — not WiFi.
    2. C6 only — release the device before proceeding: stop all VCI management processes and services listed in Section 4. Not all listed items are present on every machine — stop whichever apply and confirm none remain active.
    3. Verify Windows shows an active network link on the NIC connected to SD Connect.
    4. Install eLinehub Mechanic on the workshop Windows PC.
    5. Open eLinehub Mechanic, create a new order and share the Passcode with the Technician. No XENTRY, DTS Monaco, Vediamo or Mercedes Online credentials are required on the Mechanic PC.
  • Technician Side — Remote Specialist

    An eLinehub subscription or Credits are required. Sign in to the Technician Web App to check your account’s current trial eligibility and terms.

    1. Install eLinehub Technician on the PC that already has XENTRY, DTS Monaco and/or Vediamo with Mercedes Online credentials configured.
    2. Sign in and accept the order by entering the Passcode shared by the Mechanic. If the workshop uses a Custom Mechanic build, orders are auto-assigned.
    3. Select Mechanic Network Adapter. Keep eLinehub Link for a supported Link setup. For a fixed-IP RJ45 connection, select a physical network adapter.
    4. For SD Connect C4 over RJ45 when XENTRY requires a fixed IP, use physical network bridging. In a local loopback, leave the bridge-side interface on automatic IP and apply the required static address to the separate diagnostic interface. Use the OEM network settings for your configuration and check for address conflicts.
    5. Launch XENTRY Diagnosis (and DTS Monaco or Vediamo if needed). SD Connect appears as a locally connected device on the 172.29.x.x network. Mercedes online coding — SCN coding, FDOK authorization and online programming — all run through your own Mercedes Online account directly from this PC.
8 — Connection Requirements

Network quality

A wired internet connection is recommended at both ends. Use the eLinehub network quality test and review the results shown in the interface. The technician decides whether the connection suits the job. Follow the vehicle manufacturer’s procedure before writing. Network test results alone do not establish that a write can begin.

If the network degrades while a write is active, follow the applicable manufacturer procedure. Do not disconnect solely because of a network reading. If the connection drops during programming, follow the manufacturer’s recovery procedure for the affected module and stage. A restored connection does not mean it is safe to restart the write.

DoIP internet continuity: when SD Connect is bridged and the vehicle’s DoIP network has an active gateway, the Technician PC’s internet may drop while the diagnostic session stays active. Use the Switch button in eLinehub to toggle between diagnostic priority mode and normal internet mode — only between sessions, never during SCN coding or flash.

9 — Business Control

Customer Protection and Business Control

Check the order type and the instructions shown in the app. Passcode orders, orders sent through a branded app, and team assignments are separate paths.

  • Passcode Order Protection

    If the order asks for a Passcode, follow the instructions shown in the Web App or Windows app.

  • Custom Mechanic Build

    In the branded Mechanic app, check where the order will be sent before submitting it.

  • Secure Order Sharing

    For a team assignment, check the recipient in the order details before connecting. Check what the assigned partner can see before sharing an order. Vehicle and job details can identify a workshop even when its name is hidden.

10 — Platform Support

Mercedes-Benz Platform and Protocol Compatibility

Vehicle Series

  • C-Class (W204, W205, W206)
  • E-Class (W212, W213, W214)
  • S-Class (W221, W222, W223)
  • GLC (W253, X254)
  • GLE (W166, W167)
  • GLS, CLA, CLS
  • Check compatibility for the exact vehicle, software and interface before starting. The examples on this page do not establish coverage for every combination.
  • EQA, EQB
  • Sprinter (W906, W907)
  • Vito (W447)
  • AMG and Maybach variants

Vehicle Architectures

  • Classic CAN / K-Line (W204/W212)
  • MRA2
  • EVA2
  • MMA
  • EQ Series (full DoIP)

Protocols

  • K-Line
  • CAN
  • CAN FD
  • FlexRay
  • DoIP / Ethernet
  • UDS
  • ISO-TP

Online Functions

  • SCN coding
  • Mercedes online coding
  • Online programming
  • FDOK
  • Seed-key authentication
  • EIS/EZS online pairing
  • SOC commissioning
11 — Common Questions

Mercedes SD Connect Remote Diagnostics FAQ

Nine questions covering XENTRY remote setup, SCN coding, C4/C6 device configuration and the 2021+ Xentry certificate requirement.

Can I run XENTRY Diagnosis remotely with SD Connect C4 or C6?
Check the exact SD Connect interface, XENTRY version and network setup. Confirm device discovery in XENTRY before beginning. Recognition does not establish that every operation is supported.
What is the difference between eLinehub and remote desktop for XENTRY remote diagnostics?
With remote desktop, XENTRY runs on the workshop PC using that computer’s VCI connection. The software licensing, account access and security arrangements for that environment need to be assessed. eLinehub bridges the SD Connect network adapter so XENTRY can run on the Technician PC instead. Moving the software does not by itself establish permission to perform a coding or programming job.
Does SCN coding work in a remote XENTRY session via eLinehub?
The network bridge makes the SD Connect connection available on the Technician PC. Configure the interface for the exact VCI and XENTRY setup, then use your own Mercedes Online credentials for SCN coding.
Can DTS Monaco and Vediamo be used remotely via SD Connect?
DTS Monaco and Vediamo need an interface configured for the specific SD Connect and software version. Use the bridge and OEM network settings for that configuration.
What is the difference between SD Connect C4 and C6 for remote use?
C4 works with eLinehub after a straightforward Ethernet connection with no additional preparation. C6 requires stopping local VCI management processes and services before sharing, to release the device. Not all listed processes and services exist on every machine — which ones are present depends on the C6 or VXDIAG driver version installed. Stop whichever apply and confirm none remain active. This step is required at the start of each session.
How do I configure the static IP for XENTRY with eLinehub?
For SD Connect C4 over RJ45 when XENTRY requires a fixed IP, use physical network bridging. In a local loopback, leave the bridge-side interface on automatic IP and apply the required static address to the separate diagnostic interface. Use the IP, subnet mask and gateway specified for that configuration and check for conflicts with the workshop or other local interfaces.
Does the Mechanic need XENTRY installed?
The Mechanic only needs the SD Connect connected via Ethernet to the workshop PC and eLinehub Mechanic installed. XENTRY, DTS Monaco and Vediamo stay on the Technician PC — installing diagnostic software on the Mechanic PC is not recommended and not required.
Do I need a Xentry diagnostic certificate for 2021-and-later vehicles?
For W206, W223, X167 facelift, W214, EQS, EQE and other vehicles with the secure gateway architecture, XENTRY requires a Xentry diagnostic certificate (ZenZefi format) for offline guided diagnostics and adaptations. The certificate is held by the Technician independently. eLinehub does not affect certificate authentication. SCN coding runs through the live Mercedes Online session and is not blocked by the certificate requirement.
How do I confirm who will handle an order?
For a Passcode order, follow the app’s instructions for sharing and accepting the code. For a branded app or team assignment, check the destination and who is assigned before work starts. Check what the assigned partner can see before sharing an order. Vehicle and job details can identify a workshop even when its name is hidden.

Start Your First Remote XENTRY Session

Sign in to the Technician Web App to check your account’s current trial eligibility and terms.

Questions or setup support: support@elinehub.com